Fixes:
Corrected a problem where a drive’s size was incorrectly reported to Drobo Dashboard
Previous Fixes from 1.3.3 and 1.3.4
-Fixed compatibility issue with Second Generation Drobo and Mac OS 10.4 when using the FireWire connection
-Improved USB compatibility with Mac OS X (upgrade to 10.5.8 or later)
-Resolved connectivity problem with Drobo Dashboard for some FireWire cards on Windows XP and Windows Vista
-Fixed capacity miscalculation issue that could occur when the Drobo is almost full
Windows Vista Specific
-Symptom: Full format does not complete with Windows Vista (#1651).
Condition: Drobo will not support a full format from Vista for a volume bigger than the space available.
Workaround: Choose the quick format option if you use Windows Vista to format Drobo.
Windows Server 2003 Specific
-Symptom: Drobo formatted as FAT32 not recognized by Windows Server 2003 (#2496).
Condition: If Drobo is formatted in FAT32 using the Drobo Dashboard or a different OS, such as XP, Windows Server 2003 does not recognize the FAT32 volume.
Workaround: Use the Disk Manager OS utility on Windows Server 2003 to manually assign the FAT32 volume a drive letter.
It is highly recommended to always use the most recent driver version available.
Do not forget to check with our site as often as possible in order to stay updated on the latest drivers, software and games.
Try to set a system restore point before installing a device driver. This will help if you installed a wrong driver. Problems can arise when your hardware device is too old or not supported any longer.